I
Insulators of this
group include insulators for overhead traction lines, and are divided
into two groups:
- Long-rod insulators
with solid core
- Pin type insulators
Long-rod insulators
with solid core are usually used for 25 kV 50 Hz alternating voltage
trolley lines.
These insulators
are manufactured with increased leakage distance.
Pin type unsulators
are designed with DELTA shape for use in direct current overhead traction
lines.
Insulators are made
of special porcelain mass C120 according to IEC-672-3 (JUS N.A8.302)
|
|
|
|
|
|
|
Strut insulator for overhead traction
lines 25kV 50Hz
|
 |
|
| Cat.
No. |
Low
Frequency Withstand Voltage
kV |
Leakage
distance
mm |
| Dry |
Wet |
| Horisontaly |
Verticaly |
| 5.04.30 |
150 |
125 |
100 |
725 |
|
50%
Impuls Flashover Voltage
kV |
Routine
Test Tensile Strength
daN |
Minimal
Breaking Tensile Strength
daN |
Mean
Value Breaking Tensile Strenght
daN |
Minimum
Breaking Moment Cantilever Strenght
daNm |
Weight
kg |
| Negative |
Positive |
| 300 |
270 |
2430 |
5400 |
6000 |
100 |
10,8 |
|
|
|
|
Feeder
support insulator for overhead traction lines
25kV,50Hz
|
|
|
 |
Insulators
are made of ceramic material KER 110.2 according to DIN 40685. Standard
glaze colour is brown. Unless otherwise stated, rough dimensional
tolerances according to JUS
B.D7.030 ili IEC383.
±(0,04d+1,5)mm
d<300
d - being nominal dimension in mm
| Cat.
No. |
Type |
H±10
mm |
h1
mm |
h2
mm |
D
mm |
d1
mm |
d2
mm |
| 5.04.31 |
IOV-85 |
420 |
60 |
51 |
200 |
85 |
160 |
| 5.04.43 |
IOV-110 |
485 |
88 |
88 |
225 |
110 |
160 |
|
|
|
| Cat.
No. |
Low
Frequency Withstand Voltage
kV |
Leakage
distance
mm |
Routine
Test Tensile Strength
daN
|
Minimal
Breaking Tensile Strength
daN |
Minimum
Breaking Moment Cantilever Strenght
daNm |
| Dry |
Wet |
| 5.04.31 |
135 |
95 |
790 |
2700 |
6000 |
350 |
| 5.04.43 |
135 |
95 |
790 |
2700 |
6000 |
550 |
|
Cat. No. |
50%
Impuls Flashover Voltage
kV |
Mean
Value Breaking Tensile Strenght
daN |
Minimum
Breaking Moment Cantilever Strenght
daNm |
Weight
kg |
| Negative |
Pozitive |
| 5.04.31 |
290 |
210 |
7000 |
370 |
16,8 |
| 5.04.43 |
290 |
210 |
7000 |
750 |
29 |
|
|
Top tie insulator for overhead
traction lines 25kV,50Hz
|
|
|

|
| Cat.
No. |
Low
Frequency Withstand Voltage
kV |
Leakage
distance
mm |
Routine
Test Tensile Strength
daN |
Minimal
Breaking Tensile Strength
daN |
| Dry |
Wet |
| Horisontaly |
Verticaly |
| 5.04.32/II |
130 |
110 |
110 |
790 |
2430 |
5400 |
|
Cat. No. |
Low
Frequency Flashover Voltage
kV |
Impuls
Withstand Voltage
kV |
Weight
kg |
| Dry |
Wet |
| Horisontaly |
Verticaly |
| 5.04.32/II |
137 |
116 |
116 |
200 |
16,8 |
|
|
Strut insulator for overhead traction
lines 25kV,50Hz
|
|
 |
| Cat.
No. |
Low
Frequency Withstand Voltage
kV |
Leakage
distance
mm |
Mean
Value Breaking Tensile Strenght
daN |
Minimal
Breaking Tensile Strength
daN |
| Dry |
Wet |
| Horisontaly |
Verticaly |
| 5.04.58 |
130 |
110 |
110 |
790 |
4485 |
7475 |
|
Cat. No. |
Low
Frequency Flashover Voltage
kV |
Impuls
Withstand Voltage
kV |
Minimum
Breaking Moment Cantilever Strenght
daNm |
Weight
kg |
| Dry |
Wet |
| Horisontaly |
Verticaly |
| 5.04.58 |
137 |
116 |
116 |
200 |
236 |
15,4 |
|
|
Strut
insulator for overhead traction lines 25kV,50Hz
for
polluted area |
|
 |
|
| Cat.
No. |
Low
Frequency Withstand Voltage
kV |
Leakage
distance
mm |
Mean
Value Breaking Tensile Strenght
daN |
Minimal
Breaking Tensile Strength
daN |
| Dry |
Wet |
| Horisontaly |
Verticaly |
| 5.04.59 |
130 |
110 |
110 |
1070 |
4485 |
7475 |
|
Cat. No. |
Low
Frequency Flashover Voltage
kV |
Impuls
Withstand Voltage
kV |
Minimum
Breaking Moment Cantilever Strenght
daNm |
Weight
kg |
| Dry |
Wet |
| Horisontaly |
Verticaly |
| 5.04.59 |
137 |
116 |
116 |
200 |
236 |
18,2 |
|
|
Insulator
for overhead traction lines with
working
voltage up to 1500V
|
|
|

Strut bracket insulator 5.04.41

Support insulator 5.04.42
|

Cantilever
top insulator 5.04.40
| Cat.
No. |
Voltage
V |
Minimal
Breaking Tensile Strength
daN |
Weight
kg |
| Nominal |
Maximum |
| 5.04.40 |
1500 |
1800 |
1400 |
2,6 |
| 5.04.41 |
1500 |
1800 |
2400 |
4,7 |
| 5.04.42 |
1500 |
1800 |
1400 |
2,8 |
|
|
|
|
|
|
Line
post insulators for overhead
traction
lines 3000V D.C. |
|

Copper thimble
5.01.1.4.43 |
|
|
|
|
| Cat.
No. |
Type |
Low
Frequency Flashover Voltage
kV |
Puncture
Voltage
daN |
Weight
kg |
| Dry |
Wet |
| 5.01.1 |
EŽ-1 |
90 |
60 |
170 |
4,6 |
| 5.01.1/1 |
EŽ-1S |
90 |
60 |
170 |
4,5 |
|
|
Line
post insulators for overhead
traction
lines 3000V D.C. |
|

|
| Cat.
No. |
Type |
Low
Frequency Flashover Voltage
kV |
Puncture
Voltage
daN |
Weight
kg |
| Dry |
Wet |
| 5.01.1 |
EŽ-1 |
90 |
60 |
170 |
4,6 |
| 5.01.1/1 |
EŽ-1S |
90 |
60 |
170 |
4,5 |
|
|
|
|
|
Insulators
for overhead traction lines
with
working voltage up to 750V
|

Insulator Cat. No. 5.05.5
Insulator Cat. No. 5.06.13

Saddle type insulator
5.04.54
Insulator Cat. No. 5.06.12
|
|
| Cat.
No. |
Glaze
Colour |
Voltage
V |
Weight
kg |
| Nomonal |
Maximum |
| 5.05.5 |
braon |
750 |
900 |
0,410 |
| 5.04.54 |
braon |
750 |
900 |
0,330 |
| 5.06.12 |
bela |
750 |
900 |
0,400 |
| 5.06.13 |
bela |
750 |
900 |
0,420 |
|